GFCI 测试方法制作日期:May 30,2004
-----仅供参考-----
库beplayapp体育下载分享
测试抽样
GFCI要求Quarterly testing;
首先,查看procedure,看工厂申请的产品那些要求做Quarterly testing,UL把他们分成了几个组。
如果只有一组,侧只有一种测试方法,选同种model的GFCI 3pcs;测试顺序如下
voltage surge(高压脉冲)→overload(过载)→endurance(疲劳性)→ground-fault calibration(灵敏性)——→dielectric voltage-withstand(高压)→
库beplayapp体育下载分享
如果多于一组GFCI有Quarterly testing 要求,at the manufacturer’s option,the endurance and overload tests may be performed on separate samples.
if the manufacturer chooses this option,two or three sets of sample shall be selected form each group,
假如工厂选择抽样两sets,6pcs ; 测试方法如下:
The first set: voltage surge(高压脉冲)→overload(过载)→ground-fault calibration(灵敏性)→dielectric voltage-withstand(高压)→;
The second set: endurance(疲劳性)→ground-fault calibration(灵敏性)→dielectric voltage-withstand(高压)→
库beplayapp体育下载分享
选择三sets、9pcs,测试顺序如下:
The first set: voltage surge(高压脉冲)→ground-fault calibration(灵敏性)→dielectric voltage-withstand(高压)→→→;
The second set: overload(过载)→endurance(疲劳性)→
ground-fault calibration(灵敏性)→dielectric voltage-withstand(高压)→→→;
The third set: endurance(疲劳性)→ground-fault calibration(灵敏性)→dielectric voltage-withstand(高压)→→→;
库beplayapp体育下载分享
1st . Voltage surge test (高压脉冲)
测试条件:
(额定)voltage,这一电压源提供一个载波;
(60HZ)产生设备应有50ohms的冲击阻抗,当冲击电压产生设备没有负载时(即未接上GFCI之前),应该满足三个条件:
℅上升到90℅;
;
,后续波形振幅是前一波形的60℅.
库beplayapp体育下载分享
3. 按下GFCI的reset键,将其锁住,这样输入与输出才导通,才起保护作用;
,并连接好示波器,产品接地端连接到供电端的中性导体上(这个主要是因为外壳如果是金属的,可能带电,对测试人员的完全构成威胁,如果外壳是塑胶等非导电材质,可以不接,对测试结果没有影响),
测试时,测3个controlled applications(如:0 °C 、90 °C 、-90 °C )每个相位一次或10个随机的相位。一pcs的测试要在60S内完成。
先打6000VDC (相位 0°C、90°C、270°C)
后打3000VDC (相位 0°C、90°C、270°C)
库beplayapp体育下载分享
接受条件: reset键可以跳开,但不能起火及有电击危险。 reset键不能跳开。 -----(参照943标准 )
2st . overload (过载)
测试条件:
;
;电压是GFCI的额定电压;
库beplayapp体育下载分享
-(用功率因数表来测量)。
not less than 额定电压的85℅;
-105℅之间;
的保险丝应连接在输入电压的零线与产品的接地端之间;
,是通电1s,断电9s(标准上要求通电1s,没有说断电几秒,但如果按每分六次,10s一个循环,断
beplayapp体育下载GFCI测试方法 来自beplayapp体育下载www.apt-nc.com转载请标明出处.